SL10 40002 – 40 ohm / 2 Amp Inrush Current Limiter

SL10 40002
UL Rated Inrush Current

Inrush Current Limiters

Thermistors - ISO Approved
Mechanical Specifications (mm)
D: 11.00
T: 6.00
Lead Diameter: 0.50
S: 5.10
L: 38.00
Coating Run Down
Straight Lead
3.50
B: 6.35
C: 2.75
Inrush Current Limiter Dimensions
Electrical Specifications
Resistance: 40 Ω ± 20%
Max Steady State Current up to 25°c 2 A
Max Recommended Energy 15 J
Actual Energy Failure 40 J
Resistance @ 100% Max Current: 0.65 ohm
Resistance @ 50% Max Current: 1.55 ohm
BodyTemperature @ Max Current 142°c
Dissipation Constant: 11 mw/°c
Thermal Time Constant: 25 mw/s
Material Type (for Beta and Curve) H

 

SL10 40002
Date: 07/14/2014 Drawn By: Erin Landis
Ametherm, Inc
961 Fairview Drive
Carson City, NV 89701
www.ametherm.com
Approved By: Mehdi Samii
Revision:C

Bookmark the permalink.