SL10 4R004 – 4 ohm / 4 Amp Inrush Current Limiter

SL10 4R004
UL Rated Inrush Current
CSA Approved Inrush Current
Thermistors - ISO Approved
Mechanical Specifications (mm)
D: 10.00
T: 5.00
Lead Diameter: 0.50
S: 6.30
L: 38.00
Coating Run Down
Straight Lead
3.00
B: 6.30
C: 2.20
Inrush Current Limiter Dimensions
Electrical Specifications
Resistance: 4 ± 20%
Max Steady State Current up to 25°c 4 A
Max Recommended Energy 20 J
Actual Energy Failure 40 J
Max Capacitance @ 120 VAC: 0 µ
Max Capacitance @ 240 VAC: 0 µ
Max Capacitance @ 480 VAC: 0 µ
Max Capacitance @ 680 VAC: 0 µ
Resistance @ 100% Max Current: 0.14 ohm
Resistance @ 50% Max Current: 0.29 ohm
BodyTemperature @ Max Current 160°c
Dissipation Constant: 10.5 mw/°c
Thermal Time Constant: 30 mw/s
Material Type (for Beta and Curve) A

 

SL10 4R004
Date: 02/14/2012 Drawn By: Erin Landis
Ametherm, Inc
961 Fairview Drive
Carson City, NV 89701
www.ametherm.com
Approved By: Mehdi Samii
Revision: