SL12 50002 – 50 ohm / 2 Amp Inrush Current Limiter

SL12 50002
UL Rated Inrush Current
Thermistors - ISO Approved
Mechanical Specifications (mm)
D: 13.00
T: 5.00
Lead Diameter: 0.80
S: 7.80
L: 38.00
Coating Run Down
Straight Lead
3.00
B: 5.65
C: 3.42
Inrush Current Limiter Dimensions
Electrical Specifications
Resistance: 50 ± 20%
Max Steady State Current up to 25°c 2 A
Max Recommended Energy 20 J
Actual Energy Failure 40 J
Max Capacitance @ 120 VAC: 1389 µ
Max Capacitance @ 240 VAC: 347 µ
Max Capacitance @ 480 VAC: 0 µ
Max Capacitance @ 680 VAC: 0 µ
Resistance @ 100% Max Current: 0.65 ohm
Resistance @ 50% Max Current: 1.33 ohm
BodyTemperature @ Max Current 142°c
Dissipation Constant: 12.7 mw/°c
Thermal Time Constant: 47 mw/s
Material Type (for Beta and Curve) I

 

SL12 50002
Date: 11/11/2008 Drawn By: Erin Landis
Ametherm, Inc
961 Fairview Drive
Carson City, NV 89701
www.ametherm.com
Approved By: Mehdi Samii
Revision:a